Back
Where to buy Contact us
PHP-7.2kV-8.25kV-BoltOn-Tran-Photos

7.2 kV / 8.25kV Bolt-On Mount Transformer Fuses

Approvals & Standards
Some UL Listed to standard File E143362

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.

Key features & benefits

  • UL listed for compatibility with UL listed equipment

  • Bolt-In mounting for direct connection to bus or terminals

  • Current-limiting for superior equipment protection

  • Non-venting for silent operation

  • Metal embossed catalog number and manufacturing date for lasting identification

  • Outdoor usage for the 9F62

  • Blown-fuse indicator to give positive identification of open fuse

  • Amp trap: 2 lb tripped force - 0.50 Inch

  • 9F62: 0.125 lb tripped force – 0.20 Inch

Applications

  • Protection for 5.5kV to 15.5kV transformers or distribution systems

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 125 to 400 A
Speed/Characteristic E-Rated
Reach Compliant Yes
Max Operating Temp. 80 °C

Reference Finder

18 references in this series

Scroll

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight Sort ascending
A083B1DAR0-15E See product
5A - - No 5.4431kg
A083B1DAR0-10E See product
10A - - No 5.4431kg
A083B1DAR0-20E See product
20A - - No 5.4431kg
A083B1DAR0-25E See product
25A - - No 5.4431kg
A083B1DAR0-30E See product
30A - - No 5.4431kg
A083B1DAR0-40E See product
40A - - No 5.4431kg
A083B1DAR0-50E See product
50A - - No 5.4431kg
A083B1DAR0-65E See product
65A - - No 5.4431kg
A083B1DAR0-80E See product
80A - - No 5.4431kg
A083B1DAR0-100E See product
100A - - No 5.4431kg
Back to top