7.2 kV / 8.25kV Bolt-On Mount Transformer Fuses
Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.
Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end mounts designed for bolting directly to equipment bus or terminal pads.
Product data sheets
- DS-7.2-8.25kV-Bolt-On-Mount-Transformer-Protection-Mersen
pdf - 311.76 KB
Product Applications
Key features & benefits
UL listed for compatibility with UL listed equipment
Bolt-In mounting for direct connection to bus or terminals
Current-limiting for superior equipment protection
Non-venting for silent operation
Metal embossed catalog number and manufacturing date for lasting identification
Outdoor usage for the 9F62
Blown-fuse indicator to give positive identification of open fuse
Amp trap: 2 lb tripped force - 0.50 Inch
9F62: 0.125 lb tripped force – 0.20 Inch
Applications
Protection for 5.5kV to 15.5kV transformers or distribution systems
Frequency (Hz) | 50/60 Hz |
Amperage Range | 125 to 400 A |
Speed/Characteristic | E-Rated |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853510 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight Sort ascending |
---|---|---|---|---|---|
A083B1DAR0-15E See product
|
5A | - | - | No | 5.4431kg |
A083B1DAR0-10E See product
|
10A | - | - | No | 5.4431kg |
A083B1DAR0-20E See product
|
20A | - | - | No | 5.4431kg |
A083B1DAR0-25E See product
|
25A | - | - | No | 5.4431kg |
A083B1DAR0-30E See product
|
30A | - | - | No | 5.4431kg |
A083B1DAR0-40E See product
|
40A | - | - | No | 5.4431kg |
A083B1DAR0-50E See product
|
50A | - | - | No | 5.4431kg |
A083B1DAR0-65E See product
|
65A | - | - | No | 5.4431kg |
A083B1DAR0-80E See product
|
80A | - | - | No | 5.4431kg |
A083B1DAR0-100E See product
|
100A | - | - | No | 5.4431kg |