7.2 kV / 8.25kV Ferrule Mount Transformer Fuses

Approvals & Standards
Some UL listed to standard File E143362

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Key features & benefits

  • Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

  • Ferrule mounting for standard clips and interchangeability with other brands of fuses

  • Current-limiting for superior equipment protection

  • Non-venting for silent operation

  • Metal embossed catalog number and manufacturing date for lasting identification

  • Outdoor usage for the 9F62 and 9F60 type EJO

  • Blown-fuse indicator to give positive identification of open fuse: Amp-Trap: 2" Barrel 1 lb tripped force - 0.19 Inch; Amp-Trap: 3" Barrel 2 lb tripped force - 0.50 Inch; 9F60/9F62: 0.125 lb tripped force – 0.20 Inch

Applications

  • Protection for 6.9 kV to 8.3 kV transformers or distribution systems.

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 10 to 200 A
Speed/Characteristic E-Rated
Reach Compliant Yes
Max Operating Temp. 80 °C

Reference Finder

Item number Ampere rating Sort descending Fuse size Clearing I2t At Rated Voltage Indication System Product weight
9F60DJE905 See product
0.5A - - Yes 1.701kg
9F60FJE100 See product
100A - - Yes 4.0823kg
9F62DCC100 See product
100A - - Yes 3.6287kg
A825X100E-1 See product
100A - - Yes 4.5359kg
9F60DJE010 See product
10A - - Yes 1.701kg
A825X10E-1 See product
10A - - Yes 4.5359kg
9F60HJE125 See product
125A - - Yes 7.0307kg
9F62DCC125 See product
125A - - Yes 3.6287kg
A825X125E-1 See product
125A - - Yes 8.8451kg
9F60HJE150 See product
150A - - Yes 7.0307kg
Back to top