Back
Where to buy Contact us
PHP-A2D-photos

A2D-R - Class RK1 - Time-Delay

Approvals & Standards
UL listed to standard 248-12 File E2137
DC listed to UL standard 248
CSA certified to standard C22.2 No. 248.12

Amp-Trap 2000 time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Amp-Trap 2000 time-delay A2D-R fuses provide IEC Type 2 "no damage" protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace older 250V Class H, K or RK5 fuses already installed in the field.

Key features & benefits

  • Non-indicating or Solid state SmartSpot visual blown fuse indicator

  • Time-delay for motor starting and transformer inrush currents without nuisance opening

  • 600VAC & 600VDC dual rated

  • 300kA interrupting rating - self-certified, UL witnessed tests

  • Extremely current-limiting for low peak let-thru current

  • Recommended for Arc Flash energy reduction

  • Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black outs”

  • Rejection-style design prevents replacement errors (when used with recommended fuse blocks)

  • High-visibility orange label gives instant brand recognition

  • Reduced inventory by taking the place of class RK5, K, and H fuses

  • Metal-embossed date and catalog number for easier traceability and lasting identification

  • Fiberglass body provides dimensional stability in harsh industrial settings

Applications

  • Motors

  • Safety switches

  • Transformers

  • Branch circuit protection

  • Disconnects

  • Control panels

  • All general-purpose circuits

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 1/10 to 600 A
Fuse Class Class RK1
Speed/Characteristic Time Delay
Flammability Rating 94 V-0

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight Sort ascending
A2D450R See product
450A - - Yes 1.3304kg
A2D450RN See product
450A - - No 1.3304kg
A2D500R See product
500A - - Yes 1.3304kg
A2D500RN See product
500A - - No 1.3304kg
A2D600R See product
600A - - Yes 1.3304kg
A2D600RN See product
600A - - No 1.3304kg
A2D225R See product
225A - - Yes 0.7439kg
A2D225RN See product
225A - - No 0.7439kg
A2D250R See product
250A - - Yes 0.7439kg
A2D250RN See product
250A - - No 0.7439kg
Back to top