Approvals & Standards
IEC/EN 60 947-3
For NH-fuse links size 1 in accordance with IEC/EN 60 269, VDE 0636

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 800Vac range includes Size 1 Multivert rated at 160A and answers the specific needs of Photovoltaic application for using String inverters rated at 800Vac. Multivert 800Vac are used for installation on to 185mm bus bar systems. MULTIVERT® 800Vac are designed for NH fuse-links in accordance with IEC/EN 60269, VDE 0636, size 1: 160A. The system is a modular system, that allows the installation of the individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 800Vac range includes Size 1 Multivert rated at 160A and answers the specific needs of Photovoltaic application for using String inverters rated at 800Vac. Multivert 800Vac are used for installation on to 185mm bus bar systems. MULTIVERT® 800Vac are designed for NH fuse-links in accordance with IEC/EN 60269, VDE 0636, size 1: 160A. The system is a modular system, that allows the installation of the individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

Key features & benefits

  • Installation on to 185mm bus bar system

  • Standard design with M 12 screws: M = 35 ±3Nm

  • Direct installation without drilling with hooked clamps possible

  • Symmetrical switch - top/bottom cable terminal connection

  • Touch protection IP 30 with central cover

  • Varieties of cable termination: bolt, insert nut, V-terminal.

  • Other terminations on demand

  • Safe on load connection/disconnection in accordance with IEC 60947-3

Applications

  • Power distibution and Motor protection

  • Photovoltaic application: Protection on lines of String inverters rated at 800Vac

Technical Specifications
Frequency (Hz) 50 ... 60 Hz
Short Circuit Current Rating (SCCR) Ue=AC 800 V; Ie=160 A 10kA
CE Conformity Yes
Reach Compliant Yes
Degree of Protection (IP) IP30

Reference Finder

6 references in this series

Scroll

Item number Fuse size Number of poles Product weight Sort ascending
L1069372 - 8.150.000 See product
1 3-Pole 4.67kg
M1069373 - 8.160.000 See product
1 3-Pole 4.63kg
N1069374 - 8.170.000 See product
1 3-Pole 4.55kg
H1069369 - 8.100.000 See product
1 3-Pole 4.52kg
J1069370 - 8.110.000 See product
1 3-Pole 4.46kg
K1069371 - 8.120.000 See product
1 3-Pole 4.38kg
Back to top