B1000271 - 45DB120V80PTD
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 80A d65mm, L292mm With Thermal Striker 80N
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 80A d65mm, L292mm With Thermal Striker 80N
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Item number | B1000271 |
Catalogue No | 45DB120V80PTD |
Description | High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 80A d65mm, L292mm With Thermal Striker 80N |
EAN/UPC Code | 3605340455809 |
Rated voltage AC IEC | 12 kV |
Ampere Rating | 80 A |
AC or DC | AC |
Fuse Size | d=65mm, L=292mm |
Mounting | Clip |
Clearing I2t At Rated Voltage | 87 kA²s |
AC Max I.R./Breaking Capacity: I1 | 63 kA |
Min Interrupting Rating (MBC) | 345 A |
Design Details | VDE T402 |
Indication System | Yes |
Indication System Type | Striker |
Connection/Terminal Material | Silver-Plated Copper |
Connection/Terminal Type | Cylindrical |
Product Diameter | 2.56 in |
Product Length | 14.09 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 4.85 lb |
Sell Pack Width | 2.64 in |
Sell Pack Length | 15.35 in |
Sell Pack Height | 2.64 in |
Product group | High Voltage IEC Fuses |
Body/Insulating Material | Ceramic |
Product Weight | 4.85 lb |
Power Dissipation at Rated Current Value | 85 W |