M1023143 - 1.001.725
NH fuse-switch disconnector MULTIVERT® Size 00 160A 3x1-Pole switching Bus bar system 185mm V-terminal V-clamp
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 185 mm single pole switching are for installation on to 185 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
NH fuse-switch disconnector MULTIVERT® Size 00 160A 3x1-Pole switching Bus bar system 185mm V-terminal V-clamp
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 160A 185 mm single pole switching are for installation on to 185 mm bus bar systems. MULTIVERT® 160A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Datasheets
Compliances
pdf - 212.72 KB
pdf - 224.71 KB
| Item number | M1023143 |
| Catalogue No | 1.001.725 |
| Description | NH fuse-switch disconnector MULTIVERT® Size 00 160A 3x1-Pole switching Bus bar system 185mm V-terminal V-clamp |
| EAN/UPC Code | 9008567002865 |
| Frequency (Hz) | 50 ... 60 Hz |
| Rated voltage AC IEC | 690 V |
| Ampere Rating | 160 A |
| Utilization Category | AC 22 B @ Ue = AC 400 V; Ie = 160 A AC 20 B @ Ue = AC 690 V; Ie = 160 A |
| Switchability | 3x1-pole switching |
| ROHS Compliant | Yes |
| AC or DC | AC |
| Short Circuit Current Rating (SCCR) | 80kA@Ue = AC 500 V; Ie = 160 A |
| Fuse Size | 00 |
| Design Details | with cover shroud 1.000.915 |
| Number of Poles | 3-Pole |
| Degree of Pollution | 3 |
| Rated Impulse Withstand Voltage | 4 kV |
| Rated Insulation Voltage | 1000 V |
| Rated SC Withstand | 4.2 kA / 1 s |
| Max Power dissipation of Fuse Links Pn | 12 W |
| Max Power dissipation of Solid Links Pn | 1.2 W |
| Power Dissipation by Ith without Fuse-Links | 22 W |
| Power Dissipation by Ith without Solid Links | 34 W |
| Rated short circuit making capacity with solid links Icm | 6.3 kA |
| Installation Mounting | Bus bar system 185 mm |
| Product Width | 1.97 in |
| Product Length | 4.72 in |
| Product Height | 26.14 in |
| Sell Pack Quantity | 1 EA |
| Sell Pack Weight | 4.74 lb |
| Sell Pack Width | 5.12 in |
| Sell Pack Length | 27.36 in |
| Sell Pack Height | 2.01 in |
| Product group | IEC Fuse Switch Disconnectors |
| Product Weight | 4.74 lb |
| Conventional Free Air thermal Current With Fuse-Links Ith | 160 A |
| Conventional Free Air thermal Current - Solid Links | 200 A |