Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Series
HelioProtection® HP15NH, Photovoltaic fuse-links gPV 1500VDC
Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP15NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on 1XL/2XL/3L sizes having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards.
They are available with plain blades, bolted blades for direct mounting with and without striker.
Read
Series
NH Fuse-links gBat 1000V-1500V DC
Mersen NH gBat fuse series was engineered specifically for protection of battery systems. They offer full range protection and can protect very small over currents as well as DC fault current up to 150kA. The NH gBat fuses serie covers various ratings in 1000VDC with NH1 and NH2 sizes, and in 1500VDC with NH1XL, NH2XL and NH3L sizes. They are gBat type that comply with new IEC 60269-7 standard for Battery protection. They are available with bolted type blades for direct mounting, or with plain blades.
Read
Series
Protistor® size 2x72 and 2x73 aR, 550 to 1250VAC (IEC)
The 1250V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These aR ultra-fast acting square body fuse-links are available in different body sizes, each size having multiple worldwide acceptable mounting styles.
They have been engineered to provide state-of-the-art protection for semiconductors: diodes, thyristors and IGBT devices. They are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic.
All fuse-links can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.
Read
Product
M301909 - PC76UD95V22CP11
Square Body High-Speed Fuse Protistor® 2x73 aR 950VAC IEC 2200A With Striker Plates with Metric Threaded Holes
Read
Product
S300741 - PC76UD85V28CP11
Square Body High-Speed Fuse Protistor® 2x73 aR 850VAC IEC 2800A With Striker Plates with Metric Threaded Holes
Read
Series
Protistor® size 71 aR, 750 to 1250VAC (IEC) / 1300VAC (UL)
These 1250/1300V Protistor® fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These aR ultra-fast acting square body fuse-links are available in different body sizes, each size having multiple worldwide acceptable mounting styles.
The Protistor® have been engineered to provide state-of-the-art protection for semiconductors: diodes, thyristors and IGBT devices. Fuses are assembled with die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level. All contact surfaces are silver plated and all hardware is non-magnetic.
All fuse-links can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.
Read
Product
H300525 - PC71UD11C630TF
Square Body High-Speed Fuse Protistor® Size 71 aR 1000VAC IEC 1100VAC UL 630A With Striker Flush ends metric threads
Read
Product
M301288 - PC71UD10C700TF
Square Body High-Speed Fuse Protistor® Size 71 aR 1000VAC IEC 1100VAC UL 700A With Striker Flush ends metric threads
Read
Series
OT - Class K5 - Fast-Acting
One-Time OT and OTN general purpose fuses provide low cost protection for feeder and branch-circuits serving lighting, heating, and other non-motor loads. OT and OTN fuses will safely interrupt available short-circuit currents up to 50,000 amperes in all ratings. OT and OTN fuses are not rejection fuses and care should be taken to ensure that replacement fuses do not have lower interrupting ratings than original fuses. OTN(15-60) satisfy the Canadian electrical code requirement for Type P low melting-point, non-time-delay fuses.
Read
Product
OT3
Fuse OT - Class K5 - Fast-Acting 250VAC 250VDC 3A Ferrule Amp-Trap®
Read