Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Series
HelioProtection® HP15NH, Photovoltaic fuse-links gPV 1500VDC
Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection® HP15NH fuse links are designed for the protection of cables in a PV group of chains when a short circuit occurs in a panel (main fuse category). This HelioProtection® main fuse range enlarges our PV fuse links offering on 1XL/2XL/3L sizes having a worldwide acceptance. They are of the gPV type and comply with both IEC 60269-6 and UL 2579 PV standards.
They are available with plain blades, bolted blades for direct mounting with and without striker.
Read
Series
NH Fuse-links gBat 1000V-1500V DC
Mersen NH gBat fuse series was engineered specifically for protection
of battery systems. They offer full range protection and can protect
very small over currents as well as DC fault current up to 150kA. The
NH gBat fuses serie covers various ratings in 1000VDC with NH1 and
NH2 sizes, and in 1500VDC with NH1XL, NH2XL and NH3L sizes. They are gBat type that comply with new IEC 60269-7 standard for Battery protection. They are available with bolted type blades for
direct mounting, or with plain blades.
Read
Series
Protistor® BS88-4 17x49 aR URZ/URY, 690VAC (IEC)
The 690V Protistor® BS88-4 fuse-links provide maximum flexibility in equipment design and ultimate protection for protection of power semiconductors.These fuse-links are defined as per IEC 60269-1 and -4 , VDE 636-23 and BS88-4 for a worldwide acceptance.The Protistor® have been engineered to provide state-of-the-art protection for semiconductors: diodes, thyristors, GTO's and IGBT devices. Fuses are assembled with pure silver, die-cut elements embedded in solidified sand, which helps control arcing characteristics for a lower I²t and high interrupting rating level.
Each fuse-link can be equipped with a low voltage trip-indicator which can operate a field mountable microswitch.
Read
Product
V221255 - BS17UY69V100
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 100A
Read
Product
E221264 - BS17UY69V100P
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 100A With Striker
Read
Product
R221252 - BS17UY69V71
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 71A
Read
Product
B221261 - BS17UY69V71P
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 71A With Striker
Read
Product
S221253 - BS17UY69V80
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 80A
Read
Product
C221262 - BS17UY69V80P
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 80A With Striker
Read
Product
T221254 - BS17UY69V90
British Standard fuse-link Protistor® 17x49 aR 690VAC IEC 90A
Read