Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Key features & benefits

  • Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

  • Ferrule mounting for standard clips and interchangeability with other brands of fuses

  • Current-limiting for superior equipment protection

  • Non-venting for silent operation

  • Metal embossed catalog number and manufacturing date for lasting identification

  • Outdoor usage for the 9F62 and 9F60 type EJO

  • Blown-fuse indicator to give positive identification of open fuse: Amp-Trap: 2" Barrel 1 lb tripped force - 0.19 Inch; Amp-Trap: 3" Barrel 2 lb tripped force - 0.50 Inch; 9F60/9F62: 0.125 lb tripped force – 0.20 Inch

Applications

  • Protection for 16 kV to 25 kV transformers or distribution systems.

Technical Specifications

Frequency (Hz) 50/60 Hz
Amperage Range 1/2 to 100 A
Speed/Characteristic E-Rated
Reach Compliant Yes
Max Operating Temp. 80 °C

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
9F60FNJ015 See product
15A - - Yes 5.4431kg
9F60FNJ020 See product
20A - - Yes 5.4431kg
9F60FNJ025 See product
25A - - Yes 5.4431kg
9F60FNJ030 See product
30A - - Yes 5.4431kg
9F60FNJ040 See product
40A - - Yes 5.4431kg
9F60FNJ050 See product
50A - - Yes 5.4431kg
9F60HNJ065 See product
65A - - Yes 11.7934kg
9F60HNJ080 See product
80A - - Yes 11.7934kg
9F60HNJ100 See product
100A - - Yes 11.7934kg
Back to top