5.5 kV DIN Mount Motor
Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized.
Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized.
Product data sheets
- DS-3.3kV-7.2kV-DIN-Mount-Motor-Protection-Mersen
pdf - 123.76 KB
Compliance
- COM-RoHS-RS000074-5.5kV-DIN-Mount-Motor-Mersen
pdf - 141.85 KB
- COM-REACH-RE000074-5.5kV-DIN-Mount-Motor-Mersen
pdf - 200.42 KB
Key features & benefits
Clip mount DIN 45: R-Rated fuses with North American ANSI characteristics in a standard DIN 442mm size
Current-limiting for superior equipment protection
Blown fuse indicator provides positive identification of open fuse. 4.5lb tripping force - 1.0”
Applications
Short circuit protection of medium voltage motors and motor controllers
Frequency (Hz) | 50/60 Hz |
Amperage Range | 2R to 19R |
Speed/Characteristic | R-Rated |
UL Category Code | MSSS2 |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853510 |
UL File Number | File E93367 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A055D1DSR0-12R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-13R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-16R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-19R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-2R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-3R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-4R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-5R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-6R See product
|
- | - | - | Yes | 5.6699kg |
A055D1DSR0-9R See product
|
- | - | - | Yes | 5.6699kg |
-
DEFINITIONS:
*R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating
*Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions
*Continuous Ampere Rating at 40°C: The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection
*Spring-Reinforced Clip MR45 & Spring Ref.# L096472
*Fuse-Holder: SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625
*Note: Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details