5.5kV Clip-Lock Mount Transformer Fuses
Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.
Mersen Amp-Trap fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These general purpose current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They are single, double or triple barrels 3 inch diameter (size D) and mount in unique cam-locking clips for superior connections as well as easy installation and replacement.
Product data sheets
- DS-5.5kV-Clip-Lock-Mount-Transformer-Protection-Mersen
pdf - 264.15 KB
Product Applications
Key features & benefits
UL listed for compatibility with UL listed equipment
Clip-lock mounting for reliable high integrity connection into circuit
Current-limiting for superior equipment protection
Non-venting for silent operation
Metal embossed catalog number and manufacturing date for lasting identification
Blown-fuse indicator to give positive identification of open fuse
2 lb tripped force - 0.50 Inch
Applications
Protection for 5.5kV to 15.5kV transformers or distribution systems
Technical Specifications
Frequency (Hz) | 50/60 Hz |
Amperage Range | 10 to 600A |
Speed/Characteristic | E-Rated |
UL Category Code | JEEG |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853510 |
UL File Number | File E143362 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A055C1D0R0-100E See product
|
100A | - | - | Yes | 5.4431kg |
A055C1D0R0-10E See product
|
10A | - | - | Yes | 5.4431kg |
A055C1D0R0-125E See product
|
125A | - | - | Yes | 5.4431kg |
A055C1D0R0-150E See product
|
150A | - | - | Yes | 5.4431kg |
A055C1D0R0-15E See product
|
15A | - | - | Yes | 5.4431kg |
A055C1D0R0-200E See product
|
200A | - | - | Yes | 6.8039kg |
A055C1D0R0-20E See product
|
20A | - | - | Yes | 5.4431kg |
A055C1D0R0-250E See product
|
250A | - | - | Yes | 6.8039kg |
A055C1D0R0-25E See product
|
25A | - | - | Yes | 5.4431kg |
A055C1D0R0-300E See product
|
300A | - | - | Yes | 6.8039kg |