Back
Where to buy Contact us
PHP-5.5kV-Ferrule-Mnt-Trans-Photos

5.5kV Ferrule Mount Transformer Fuses

Approvals & Standards
Some UL listed to standard File E143362

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Key features & benefits

  • Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

  • Ferrule mounting for standard clips and interchangeability with other brands of fuses

  • Current-limiting for superior equipment protection

  • Non-venting for silent operation

  • Metal embossed catalog number and manufacturing date for lasting identification

  • Outdoor usage for the 9F62 and 9F60 type EJO

  • Blown-fuse indicator to give positive identification of open fuse: Amp-Trap: 2" Barrel 1 lb tripped force - 0.19 Inch; Amp-Trap: 3" Barrel 2 lb tripped force - 0.50 Inch; 9F60/9F62: 0.125 lb tripped force – 0.20 Inch

Applications

  • Protection for up to 5.5 kV transformers or distribution systems.

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 1/2 to 450 A
Speed/Characteristic E-Rated
Reach Compliant Yes
Max Operating Temp. 80 °C

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
A055F1D0R0-10E See product
10A - - Yes 4.5359kg
A055F1D0R0-125E See product
125A - - Yes 4.5359kg
A055F1D0R0-150E See product
150A - - Yes 4.5359kg
A055F1D0R0-15E See product
15A - - Yes 4.5359kg
A055F1D0R0-175E See product
175A - - Yes 4.5359kg
A055F1D0R0-200E See product
200A - - Yes 4.5359kg
A055F1D0R0-20E See product
20A - - Yes 4.5359kg
A055F1D0R0-25E See product
25A - - Yes 4.5359kg
A055F1D0R0-30E See product
30A - - Yes 4.5359kg
A055F1D0R0-40E See product
40A - - Yes 4.5359kg
Back to top