MEV100A300-4 - MEV100A300-4
EVpack Fuse 1000VDC UL 300A Max. Rated Breaking Capacity DC: 20 kA @ 1000 V L/R ≤ 1 ms Bolted
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
EVpack Fuse 1000VDC UL 300A Max. Rated Breaking Capacity DC: 20 kA @ 1000 V L/R ≤ 1 ms Bolted
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
Datasheets
pdf - 763.17 KB
Compliances
pdf - 280.24 KB
pdf - 215.15 KB
pdf - 215.15 KB
Item number | MEV100A300-4 |
Catalogue No | MEV100A300-4 |
Description | EVpack Fuse 1000VDC UL 300A Max. Rated Breaking Capacity DC: 20 kA @ 1000 V L/R ≤ 1 ms Bolted |
EAN/UPC Code | 0782001481506 |
Rated voltage DC UL | 1000 V |
Ampere Rating | 300 A |
ROHS Compliant | Yes |
AC or DC | DC |
Mounting | Bolted |
Min Interrupting Rating (MBC) | 2920 A |
Max. Rated Breaking Capacity DC | 20 kA @ 1000 V, L/R ≤ 1 ms |
Connection/Terminal Material | Tin-Plated Brass |
Connection/Terminal Type | Bolted |
Product Diameter | 1.5 in |
Product Length | 5.08 in |
Sell Pack Quantity | 5 EA |
Sell Pack Weight | 3.318 lb |
Sell Pack Width | 5.51 in |
Sell Pack Length | 8.27 in |
Sell Pack Height | 1.77 in |
Product group | EV and Battery Protection Fuses |
Product Weight | 0.664 lb |
Power Dissipation at Intermediate Current Value | 9.5 W @ 0.5 In |