Back
Where to buy Contact us
PHP-LFCY14AM-MSL

Ferrule fuse-links 14x51 aM 500 to 690VAC

Approvals & Standards
IEC 60269-1 & -2
Approved by Lloyd's Register of Shipping and Bureau Veritas

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.

Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts. Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.

Key features & benefits

  • Reduced size

  • Striker version available for remote indication of fuse operation

  • Safest and most reliable protection system

Applications

  • aM type for protection of motors, transformers and other loads with in-rush currents.

Technical Specifications

Amperage Range 0.25 ... 50 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
B212590 - FR14AM69V0.25 See product
0.25A 14x51 - No 0.021kg
B216661 - FR14AM50V2P See product
2A 14x51 - Yes 0.021kg
C216662 - FR14AM50V45P See product
45A 14x51 - Yes 0.021kg
C218203 - FR14AM50V4P See product
4A 14x51 - Yes 0.021kg
D218204 - FR14AM50V50P See product
50A 14x51 - Yes 0.021kg
E211558 - FR14AM50V50 See product
50A 14x51 - No 0.021kg
E212593 - FR14AM50V20P See product
20A 14x51 - Yes 0.021kg
E213605 - FR14AM69V1 See product
1A 14x51 - No 0.021kg
E219240 - FR14AM50V6P See product
6A 14x51 - Yes 0.021kg
E219769 - FR14AM69V25 See product
25A 14x51 - No 0.021kg
Back to top