B210244 - FR120V63
High Voltage UTE Back-up fuse Limitor® 12kVAC IEC 63A d55mm, L520mm
FR-type fuses are designed to protect HV/LV power distribution transformers. Designed to be coordinated with other equipment, these current limiting fuse-links interrupt fault currents before they reach their peak. The fault current is interrupted inside the fuse-link body and although this is very fast, there is no sign of it outside. The 24kV fuses were specially designed with very low power losses, for use in SF6-insulated or compact air-insulated fused switchgear combinations The main elements in these fuses are: a barrel of class F insulating synthetic material, nickel plated aluminium end contacts, pure silver fuse elements and a composite material fuse element holder to withstand high temperatures. Thanks to their structure, based on a synthetic material, FR fuse-links are the perfect answer to the stress involved in use inside HV bays and fuse-link chambers.
High Voltage UTE Back-up fuse Limitor® 12kVAC IEC 63A d55mm, L520mm
FR-type fuses are designed to protect HV/LV power distribution transformers. Designed to be coordinated with other equipment, these current limiting fuse-links interrupt fault currents before they reach their peak. The fault current is interrupted inside the fuse-link body and although this is very fast, there is no sign of it outside. The 24kV fuses were specially designed with very low power losses, for use in SF6-insulated or compact air-insulated fused switchgear combinations The main elements in these fuses are: a barrel of class F insulating synthetic material, nickel plated aluminium end contacts, pure silver fuse elements and a composite material fuse element holder to withstand high temperatures. Thanks to their structure, based on a synthetic material, FR fuse-links are the perfect answer to the stress involved in use inside HV bays and fuse-link chambers.
Datasheets
pdf - 1.16 MB
Compliances
pdf - 368.44 KB
| Item number | B210244 | 
| Catalogue No | FR120V63 | 
| Description | High Voltage UTE Back-up fuse Limitor® 12kVAC IEC 63A d55mm, L520mm | 
| EAN/UPC Code | 3605340226836 | 
| Rated voltage AC IEC | 12 kV | 
| Ampere Rating | 63 A | 
| AC or DC | AC | 
| Fuse Size | d=55mm L=520mm | 
| Mounting | Clip | 
| Clearing I2t At Rated Voltage | 24 kA²s | 
| AC Max I.R./Breaking Capacity: I1 | 12.5 kA | 
| Min Interrupting Rating (MBC) | 315 A | 
| Connection/Terminal Material | Nickel-Plated Aluminum | 
| Connection/Terminal Type | Cylindrical | 
| Product Diameter | 2.17 in | 
| Product Length | 20.47 in | 
| Sell Pack Quantity | 3 EA | 
| Sell Pack Weight | 13.889 lb | 
| Sell Pack Width | 10.63 in | 
| Sell Pack Length | 24.02 in | 
| Sell Pack Height | 3.94 in | 
| Product group | High Voltage IEC Fuses | 
| Body/Insulating Material | Class F insulating synthetic material | 
| Product Weight | 4.63 lb | 
| Power Dissipation at Rated Current Value | 142 W | 