G1032959 - 45DB360V16PTS
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 16A d56mm, L537mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 16A d56mm, L537mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
| Item number | G1032959 | 
| Catalogue No | 45DB360V16PTS | 
| Description | High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 16A d56mm, L537mm With Thermal Striker 80N Low power losses | 
| EAN/UPC Code | 3605340537758 | 
| Rated voltage AC IEC | 36 kV | 
| Ampere Rating | 16 A | 
| AC or DC | AC | 
| Fuse Size | d=56mm L=537mm | 
| Mounting | Clip | 
| Clearing I2t At Rated Voltage | 2340 A²s | 
| AC Max I.R./Breaking Capacity: I1 | 32 kA | 
| Min Interrupting Rating (MBC) | 66 A | 
| Design Details | VDE T402 | 
| Indication System | Yes | 
| Indication System Type | Striker | 
| Connection/Terminal Material | Silver-Plated Copper | 
| Connection/Terminal Type | Cylindrical | 
| Product Diameter | 2.2 in | 
| Product Length | 23.74 in | 
| Sell Pack Quantity | 1 EA | 
| Sell Pack Weight | 6.173 lb | 
| Sell Pack Width | 4.33 in | 
| Sell Pack Length | 25.59 in | 
| Sell Pack Height | 3.94 in | 
| Product group | High Voltage IEC Fuses | 
| Body/Insulating Material | Ceramic | 
| Product Weight | 6.173 lb | 
| Power Dissipation at Rated Current Value | 67 W | 