S1032946 - 45DB120V16PTS2
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 16A d56mm, L292mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 16A d56mm, L292mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
Item number | S1032946 |
Catalogue No | 45DB120V16PTS2 |
Description | High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 16A d56mm, L292mm With Thermal Striker 80N Low power losses |
EAN/UPC Code | 3605340537628 |
Rated voltage AC IEC | 12 kV |
Ampere Rating | 16 A |
AC or DC | AC |
Fuse Size | d=56mm, L=292mm |
Mounting | Clip |
Clearing I2t At Rated Voltage | 3700 A²s |
AC Max I.R./Breaking Capacity: I1 | 65 kA |
Min Interrupting Rating (MBC) | 64 A |
Design Details | VDE T402 |
Indication System | Yes |
Indication System Type | Striker |
Connection/Terminal Material | Silver-Plated Copper |
Connection/Terminal Type | Cylindrical |
Product Diameter | 2.2 in |
Product Length | 11.5 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 3.527 lb |
Sell Pack Width | 2.95 in |
Sell Pack Length | 15.35 in |
Sell Pack Height | 2.95 in |
Product group | High Voltage IEC Fuses |
Body/Insulating Material | Ceramic |
Product Weight | 3.527 lb |
Power Dissipation at Rated Current Value | 21 W |