High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 40A d56mm, L292mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 40A d56mm, L292mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
| Item number | X1032950 | 
| Catalogue No | 45DB120V40PTS2 | 
| Description | High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 12kVAC IEC 40A d56mm, L292mm With Thermal Striker 80N Low power losses | 
| EAN/UPC Code | 3605340537666 | 
| Rated voltage AC IEC | 12 kV | 
| Ampere Rating | 40 A | 
| AC or DC | AC | 
| Fuse Size | d=56mm L=292mm | 
| Mounting | Clip | 
| Clearing I2t At Rated Voltage | 14 kA²s | 
| AC Max I.R./Breaking Capacity: I1 | 65 kA | 
| Min Interrupting Rating (MBC) | 134 A | 
| Design Details | VDE T402 | 
| Indication System | Yes | 
| Indication System Type | Striker | 
| Connection/Terminal Material | Silver-Plated Copper | 
| Connection/Terminal Type | Cylindrical | 
| Product Diameter | 2.2 in | 
| Product Length | 11.5 in | 
| Sell Pack Quantity | 1 EA | 
| Sell Pack Weight | 3.527 lb | 
| Sell Pack Width | 2.95 in | 
| Sell Pack Length | 15.35 in | 
| Sell Pack Height | 2.95 in | 
| Product group | High Voltage IEC Fuses | 
| Body/Insulating Material | Ceramic | 
| Product Weight | 3.527 lb | 
| Power Dissipation at Rated Current Value | 46 W | 