Limitor®- PTD Back-up Fuses, with Controlled Power Dissipation
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Product data sheets
Charts
Compliance
- COM-REACH-declaration-0054-45DB-Limitor-fuses-Medium-Voltage
pdf - 245.64 KB
Key features & benefits
High breaking capacity
High current limitation
Low switching voltage
Medium striker 80N/30mm
CPD striker: controlled power dissipation
Indoor and outdoor applications
Quick breaking
Non-ageing
Energy efficiency
New cap design for a better compatibility with all types of clips
and easier assembly
Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655
and VDE 0671-105:2003-12
Applications
HV Transformer protection
Voltage Range | 3 ... 36 kV |
Amperage Range | 6.3 ... 160 A |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A1000270 - 45DB120V63PTD See product
|
63A | d=65mm, L=292mm | 63kA²s | Yes | 2.2kg |
A1000293 - 45DB360V50PTD See product
|
50A | d=88mm, L=537mm | 40kA²s | Yes | 6.5kg |
B1000271 - 45DB120V80PTD See product
|
80A | d=65mm, L=292mm | 87kA²s | Yes | 2.2kg |
C1000272 - 45DB120V100PTD See product
|
100A | d=65mm, L=292mm | 140kA²s | Yes | 2.2kg |
D1000273 - 45DB120V125PTD See product
|
125A | d=88mm, L=292mm | 430kA²s | Yes | 3.8kg |
E1000274 - 45DB120V160PTD See product
|
160A | d=88mm, L=292mm | 670kA²s | Yes | 3.8kg |
F1000275 - 45DB240V6,3PTD See product
|
6.3A | d=56mm, L=442mm | 0.8kA²s | Yes | 2.4kg |
G1000276 - 45DB240V10PTD See product
|
10A | d=56mm, L=442mm | 2kA²s | Yes | 2.4kg |
H1000277 - 45DB240V16PTD See product
|
16A | d=56mm, L=442mm | 2.3kA²s | Yes | 2.4kg |
J1000278 - 45DB240V20PTD See product
|
20A | d=56mm, L=442mm | 3.9kA²s | Yes | 2.4kg |