PHP-Limitor®PTD-MSL

Limitor®- PTD Back-up Fuses, with Controlled Power Dissipation

Approvals & Standards
IEC 60282-1
VDE 0670 part 4
VDE 0670 part 402
DIN 43625

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.

Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.

Key features & benefits

  • High breaking capacity

  • High current limitation

  • Low switching voltage

  • Medium striker 80N/30mm

  • CPD striker: controlled power dissipation

  • Indoor and outdoor applications

  • Quick breaking

  • Non-ageing

  • Energy efficiency

  • New cap design for a better compatibility with all types of clips

  • and easier assembly

  • Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655

  • and VDE 0671-105:2003-12

Applications

  • HV Transformer protection

Technical Specifications
Voltage Range 3 ... 36 kV
Amperage Range 6.3 ... 160 A
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
T1000287 - 45DB360V10PTD See product
10A d=56mm, L=537mm 2kA²s Yes 2.7kg
V1000265 - 45DB120V20PTD See product
20A d=56mm, L=292mm 4.7kA²s Yes 1.7kg
V1000288 - 45DB360V16PTD See product
16A d=56mm, L=537mm 2.35kA²s Yes 2.7kg
W1000266 - 45DB120V25PTD See product
25A d=56mm, L=292mm 4.9kA²s Yes 1.7kg
W1000289 - 45DB360V20PTD See product
20A d=56mm, L=537mm 3.9kA²s Yes 2.7kg
X1000267 - 45DB120V32PTD See product
31.5A d=56mm, L=292mm 7kA²s Yes 1.7kg
X1000290 - 45DB360V25PTD See product
25A d=56mm, L=537mm 6.5kA²s Yes 2.7kg
Y1000268 - 45DB120V40PTD See product
40A d=56mm, L=292mm 14kA²s Yes 1.7kg
Y1000291 - 45DB360V32PTD See product
31.5A d=65mm, L=537mm 7kA²s Yes 3.7kg
Z1000269 - 45DB120V50PTD See product
50A d=56mm, L=292mm 25kA²s Yes 1.7kg