Limitor®- PTD Back-up Fuses, with Controlled Power Dissipation
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. Limitor®-PTD HV fuse-links are back-up fuses as defined in the standards: IEC 60282-1 and VDE 0670 T402 and dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuit currents. To guarantee high quality, Mersen uses the best materials: fuse-elements are in pure silver, caps are in copper coated with silver and bodies are in ceramic. Limitor®-PTD HV fuse-links are perfectly designed to be used in combination with HV switchgear. Siemens and Ormazabal recommend Limitor®-PTD HV fuses to be used in their gas-insulated switchgear.
Product data sheets
Charts
Compliance
- COM-REACH-declaration-0054-45DB-Limitor-fuses-Medium-Voltage
pdf - 245.64 KB
Key features & benefits
High breaking capacity
High current limitation
Low switching voltage
Medium striker 80N/30mm
CPD striker: controlled power dissipation
Indoor and outdoor applications
Quick breaking
Non-ageing
Energy efficiency
New cap design for a better compatibility with all types of clips
and easier assembly
Coordination with IEC 60787, IEC 62271-105, IEC/TR 62655
and VDE 0671-105:2003-12
Applications
HV Transformer protection
Voltage Range | 3 ... 36 kV |
Amperage Range | 6.3 ... 160 A |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
T1000287 - 45DB360V10PTD See product
|
10A | d=56mm, L=537mm | 2kA²s | Yes | 2.7kg |
V1000265 - 45DB120V20PTD See product
|
20A | d=56mm, L=292mm | 4.7kA²s | Yes | 1.7kg |
V1000288 - 45DB360V16PTD See product
|
16A | d=56mm, L=537mm | 2.35kA²s | Yes | 2.7kg |
W1000266 - 45DB120V25PTD See product
|
25A | d=56mm, L=292mm | 4.9kA²s | Yes | 1.7kg |
W1000289 - 45DB360V20PTD See product
|
20A | d=56mm, L=537mm | 3.9kA²s | Yes | 2.7kg |
X1000267 - 45DB120V32PTD See product
|
31.5A | d=56mm, L=292mm | 7kA²s | Yes | 1.7kg |
X1000290 - 45DB360V25PTD See product
|
25A | d=56mm, L=537mm | 6.5kA²s | Yes | 2.7kg |
Y1000268 - 45DB120V40PTD See product
|
40A | d=56mm, L=292mm | 14kA²s | Yes | 1.7kg |
Y1000291 - 45DB360V32PTD See product
|
31.5A | d=65mm, L=537mm | 7kA²s | Yes | 3.7kg |
Z1000269 - 45DB120V50PTD See product
|
50A | d=56mm, L=292mm | 25kA²s | Yes | 1.7kg |