MPDB68290
Open-Style PDB UL 1953 1000V Tin-plated Copper - 1000A Adder 1 - 12 openings; 1/2-13 x 1-3/8 --- #4-#14 Stud to Box
The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.
Open-Style PDB UL 1953 1000V Tin-plated Copper - 1000A Adder 1 - 12 openings; 1/2-13 x 1-3/8 --- #4-#14 Stud to Box
The Next Generation Power Distribution Block (PDB). Mersen power distribution blocks provide a safe and easy method of splicing cables, splitting primary power into secondary circuits and fulfilling requirements for fixed junction tap-off points. All blocks are UL and CSA approved while meeting spacing requirements for feeder and branch circuits in conjunction with UL508A and the National Electrical Code®. PDB options include single or dual conductor primary inputs and up to 30 secondary outputs. Specialty blocks are available allowing for up to 7 primary inputs. The MPDB series is offered in three size categories: miniature (MPDB62 and MPDB63 series), intermediate (MPDB66 and MPDB67 series), and large (MPDB68 and MPDB69 series), in both aluminum and copper.
Datasheets
Drawings
PDF - 120.4 KB
step - 6.5 MB
Compliances
pdf - 146.69 KB
pdf - 151.87 KB
Item number | MPDB68290 |
Description | Open-Style PDB UL 1953 1000V Tin-plated Copper - 1000A Adder 1 - 12 openings; 1/2-13 x 1-3/8 --- #4-#14 Stud to Box |
EAN/UPC Code | 782001455712 |
Rated voltage AC UL | 1000 V |
Rated voltage DC UL | 1000 V |
Frequency (Hz) | 50/60 Hz |
Ampere Rating (CU) | 1000 A |
ROHS Compliant | Yes |
AC or DC | AC/DC |
Short Circuit Rating (Class CC) | 100 kA with 30A Fuse |
Short Circuit Rating (Class G) | 100 kA with 60A Fuse |
Short Circuit Rating (Class J) | 100 kA with 600A Fuse |
Short Circuit Rating (Class L) | 100 kA with 600A Fuse |
Short Circuit Rating (Class RK1) | 100 kA with 400A Fuse |
Short Circuit Rating (Class RK5) | 100 kA with 200A Fuse |
Short Circuit Rating (Standalone) | 10 kA |
Short Circuit Rating (Class T) | 100 kA with 600A Fuse |
Number of Poles | Adder |
Connector Material | Cuivre étamé |
Number of Openings per Pole (Primary) | 1 |
Number of Openings per Pole (Secondary) | 12 |
Connector Type (Primary) | Stud |
Connector Type (Secondary) | Box |
Hex/Screw Size & Type (Primary) | - |
Hex/Screw Size & Type (Secondary) | 5/16-24 x .38 |
Hole Diameter (Secondary) | 0.272 |
Torque Rating (Primary) | stud |
Torque Rating (Secondary) | #4-#6 45; #8 40; #10-#14 35 |
Wire Range (Primary) | 1/2-13 x 1-3/8 |
Wire Range (Secondary) | #4-#14 |
Installation Mounting | Direct Screw Mount |
Product Width | 2.58 in |
Product Length | 5.7 in |
Product Height | 3.55 in |
Sell Pack Quantity | 6 EA |
Sell Pack Weight | 22.05 lb |
Sell Pack Width | 4 in |
Sell Pack Length | 5.69 in |
Sell Pack Height | 17.75 in |
Product group | Power Distribution Blocks |
Body/Insulating Material | Glass Filled Polycarbonate |
Product Weight | 3.5 lb |