K1023049 - 2.035.000
NH fuse-switch disconnector MULTIBLOC® Size 00 160A 3-Pole switching Bottom Fitting/panel Connection Clamp Strap / Screw Al/Cu clamps M8
The production programme of MULTIBLOC® series 00.ST9 comprises NH fuse switch disconnectors for 160A. They are designed for bottom fitting/panel installation and are available in triple pole units. For installation of MULTIBLOC® NH fuse switch disconnectors in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC® size 00 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00, 160A. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.
NH fuse-switch disconnector MULTIBLOC® Size 00 160A 3-Pole switching Bottom Fitting/panel Connection Clamp Strap / Screw Al/Cu clamps M8
The production programme of MULTIBLOC® series 00.ST9 comprises NH fuse switch disconnectors for 160A. They are designed for bottom fitting/panel installation and are available in triple pole units. For installation of MULTIBLOC® NH fuse switch disconnectors in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC® size 00 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00, 160A. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.
Datasheets
Compliances
pdf - 271.92 KB
Item number | K1023049 |
Catalogue No | 2.035.000 |
Description | NH fuse-switch disconnector MULTIBLOC® Size 00 160A 3-Pole switching Bottom Fitting/panel Connection Clamp Strap / Screw Al/Cu clamps M8 |
EAN/UPC Code | 9008567008584 |
Frequency (Hz) | 50 ... 60 Hz |
Rated voltage AC IEC | 690 V |
Rated voltage DC IEC | 440 V |
Ampere Rating | 160 A |
Utilization Category | AC 23 B @ Ue = AC 400 V; Ie = 160 A AC 22 B @ Ue = AC 500 V; Ie = 160 A AC 21 B @ Ue = AC 690 V; Ie = 160 A DC 22 B @ Ue = DC 220 V; Ie = 160 A DC 21 B @ Ue = DC 440 V; Ie = 100 A |
Switchability | coupure 3-pôle |
ROHS Compliant | Yes |
AC or DC | AC/DC |
Short Circuit Current Rating (SCCR) | 80kA@Ue = AC 400 V; Ie = 160 A / 80kA@Ue = AC 500 V; Ie = 160 A / 80kA@Ue = AC 690 V; Ie = 125 A |
Fuse Size | 00 |
Number of Poles | 3-Pole |
Degree of Pollution | 3 |
Rated Impulse Withstand Voltage | 8 kV |
Rated Insulation Voltage | 1000 V |
Rated SC Withstand | 4 kA / 1 s |
Max Power dissipation of Fuse Links Pn | 12 W |
Max Power dissipation of Solid Links Pn | 1.2 W |
Power Dissipation by Ith without Fuse-Links | 11 W |
Power Dissipation by Ith without Solid Links | 17 W |
Rated short circuit making capacity with solid links Icm | 6.2 kA |
Installation Mounting | Bottom Fitting/panel |
Product Width | 4.25 in |
Product Length | 3.19 in |
Product Height | 7.95 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 1.654 lb |
Sell Pack Width | 4.37 in |
Sell Pack Length | 8.07 in |
Sell Pack Height | 3.31 in |
Product group | IEC Fuse Switch Disconnectors |
Product Weight | 1.654 lb |
Conventional Free Air thermal Current With Fuse-Links Ith | 160 A |
Conventional Free Air thermal Current - Solid Links | 200 A |