X1023083 - 1.000.084
NH fuse-switch disconnector MULTIBLOC® Size 4a 1600A 1-Pole switching Bottom Fitting/panel Connection Screw M12
The production programme of MULTIBLOC® series 4a.ST8 - 1600 A comprises NH fuse switch disconnectors for 1600A. They are designed for bottom fitting/panel installation and are available in single pole and triple pole units. MULTIBLOC® size 4a are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 4a. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.
NH fuse-switch disconnector MULTIBLOC® Size 4a 1600A 1-Pole switching Bottom Fitting/panel Connection Screw M12
The production programme of MULTIBLOC® series 4a.ST8 - 1600 A comprises NH fuse switch disconnectors for 1600A. They are designed for bottom fitting/panel installation and are available in single pole and triple pole units. MULTIBLOC® size 4a are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 4a. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.
Datasheets
Compliances
Item number | X1023083 |
Catalogue No | 1.000.084 |
Description | NH fuse-switch disconnector MULTIBLOC® Size 4a 1600A 1-Pole switching Bottom Fitting/panel Connection Screw M12 |
EAN/UPC Code | 4027597023331 |
Frequency (Hz) | 50 ... 60 Hz |
Rated voltage AC IEC | 690 V |
Ampere Rating | 1600 A |
Utilization Category | AC 22 B @ Ue = AC 400 V; Ie = 1250 A AC 21 B @ Ue = AC 690 V; Ie = 1600 A DC 21 B @ Ue = DC 220 V; Ie = 1600 A DC 21 B @ Ue = DC 440 V; Ie = 1250 A |
Switchability | Comutação 1 polos |
ROHS Compliant | Yes |
AC or DC | AC |
Short Circuit Current Rating (SCCR) | 31,5kA@Ue = AC 400 V; Ie = 1600 A / 31,5kA@Ue = AC 500 V; Ie = 1600 A / 31,5kA@Ue = AC 690 V; Ie = 1600 A |
Fuse Size | 4a |
Number of Poles | 1-Pole |
Degree of Pollution | 3 |
Rated Impulse Withstand Voltage | 8 kV |
Rated Insulation Voltage | 800 V |
Rated SC Withstand | 50 kA / 1 s |
Max Power dissipation of Fuse Links Pn | 140 W |
Max Power dissipation of Solid Links Pn | 42 W |
Power Dissipation by Ith without Fuse-Links | 80 W |
Power Dissipation by Ith without Solid Links | 80 W |
Rated short circuit making capacity with solid links Icm | 100 kA |
Installation Mounting | Bottom Fitting/panel |
Product Width | 4.96 in |
Product Length | 9.17 in |
Product Height | 12.99 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 11.023 lb |
Sell Pack Width | 4.72 in |
Sell Pack Length | 13.98 in |
Sell Pack Height | 10.63 in |
Product group | IEC Fuse Switch Disconnectors |
Product Weight | 11.023 lb |
Conventional Free Air thermal Current With Fuse-Links Ith | 1600 A |
Conventional Free Air thermal Current - Solid Links | 1800 A |