B1023271 - 1.000.094
NH fuse-switch disconnector MULTIVERT® Size 4a 1250A 3x1-Pole switching Screw top terminal M16
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 1250A are for installation on to 185 mm bus bar systems. MULTIVERT® 1250A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 4a: 1250A. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
NH fuse-switch disconnector MULTIVERT® Size 4a 1250A 3x1-Pole switching Screw top terminal M16
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 1250A are for installation on to 185 mm bus bar systems. MULTIVERT® 1250A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 4a: 1250A. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Datasheets
Compliances
| Item number | B1023271 | 
| Catalogue No | 1.000.094 | 
| Description | NH fuse-switch disconnector MULTIVERT® Size 4a 1250A 3x1-Pole switching Screw top terminal M16 | 
| EAN/UPC Code | 9008567009659 | 
| Frequency (Hz) | 50 ... 60 Hz | 
| Rated voltage AC IEC | 690 V | 
| Ampere Rating | 1250 A | 
| Utilization Category | AC 22 B @ Ue = AC 500 V; Ie = 1250 A | 
| Switchability | 3x1-pole switching | 
| ROHS Compliant | Yes | 
| AC or DC | AC | 
| Short Circuit Current Rating (SCCR) | 50kA@Ue = AC 690 V; Ie = 1250 A | 
| Fuse Size | 4a | 
| Design Details | Screw top terminal | 
| Number of Poles | 3-Pole | 
| Degree of Pollution | 3 | 
| Rated Impulse Withstand Voltage | 8 kV | 
| Rated Insulation Voltage | 1000 V | 
| Rated SC Withstand | 32 kA / 1 s | 
| Max Power dissipation of Fuse Links Pn | 110 W | 
| Max Power dissipation of Solid Links Pn | 42 W | 
| Power Dissipation by Ith without Fuse-Links | 336 W | 
| Rated short circuit making capacity with solid links Icm | 68 kA | 
| Installation Mounting | Bus Bar Installation | 
| Product Width | 4.96 in | 
| Product Length | 10 in | 
| Product Height | 39.02 in | 
| Sell Pack Quantity | 1 EA | 
| Sell Pack Weight | 36.156 lb | 
| Sell Pack Width | 6.69 in | 
| Sell Pack Length | 43.31 in | 
| Sell Pack Height | 11.02 in | 
| Product group | IEC Fuse Switch Disconnectors | 
| Product Weight | 36.156 lb | 
| Conventional Free Air thermal Current With Fuse-Links Ith | 1250 A | 
| Conventional Free Air thermal Current - Solid Links | 1250 A | 
 
  