T1023126 - 1.500.004
NH fuse-switch disconnector MULTIVERT® Size 3 1260A 3x1-Pole switching Screw M12 x4
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
NH fuse-switch disconnector MULTIVERT® Size 3 1260A 3x1-Pole switching Screw M12 x4
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Item number | T1023126 |
Catalogue No | 1.500.004 |
Description | NH fuse-switch disconnector MULTIVERT® Size 3 1260A 3x1-Pole switching Screw M12 x4 |
EAN/UPC Code | 9008567007501 |
Frequency (Hz) | 50 ... 60 Hz |
Rated voltage AC IEC | 500 V |
Ampere Rating | 1260 A |
Switchability | coupure 3x1-pôle |
ROHS Compliant | Yes |
AC or DC | AC |
Short Circuit Current Rating (SCCR) | 18kA@Ue=AC500V;Ie=2 x 400A/28kA@Ue=AC500V;Ie=2 x 630A |
Fuse Size | 3 |
Number of Poles | 2 x 3-Pole |
Degree of Pollution | 3 |
Rated Impulse Withstand Voltage | 8 kV |
Rated Insulation Voltage | 1000 V |
Max Power dissipation of Fuse Links Pn | 43 W |
Installation Mounting | Bus Bar Installation |
Product Width | 7.87 in |
Product Length | 10.39 in |
Product Height | 32.44 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 30.424 lb |
Sell Pack Width | 8.27 in |
Sell Pack Length | 29.72 in |
Sell Pack Height | 7.95 in |
Product group | IEC Fuse Switch Disconnectors |
Product Weight | 30.424 lb |
Conventional Free Air thermal Current With Fuse-Links Ith | 1260 A |