Back
Where to buy Contact us
PHP-LFDID0NEFB-MSL

NEOZED D0 fuse-bases 400VAC

Approvals & Standards
DIN VDE 0636-3
DIN EN 60715

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. This system is the newest generation of screw fuse-system in the german DIN standard and is designed for 400VAC/250VDC networks. The D0 fuse-bases are available in the sizes D01, D02 and D03.

D0 fuse-bases are used in combination with D0 fuse-links for the protection of cables and power lines. D0 fuse-links limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. They also protect equipments and installations against dynamic effects of high short circuit currents.

The D0 fuse-system is installed in low voltage ditribution units, where fuse-links are accessible to non trained persons and can also be replaced by them. This system is the newest generation of screw fuse-system in the german DIN standard and is designed for 400VAC/250VDC networks. The D0 fuse-bases are available in the sizes D01, D02 and D03.

D0 fuse-bases are used in combination with D0 fuse-links for the protection of cables and power lines. D0 fuse-links limit and cut-off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. They also protect equipments and installations against dynamic effects of high short circuit currents.

Key features & benefits

  • Insulated body suitable for high mechanical and thermal impacts

  • Top and bottom contacts made of nickel plated copper alloy

  • Safe cut-off short circuits and over currents due to special design of fuse element

  • Clear indication of operation condition due coloured indicator un top contact

  • Low power dissipation

  • Optimized size

  • Resistant to aging

Applications

  • House incoming units

  • Meter distribution units

  • Distribution cabinets

  • Installation cabinets

  • Fuse boxes

Technical Specifications
Voltage Range 400 ... 440 V AC
Amperage Range 16 ... 100 A
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Fuse Type/Class Number of poles Indication System Product weight
A219144 - 01730.172000 See product
16A D01 - 3-Pole No 0.217kg
B211463 - 01720.170000 See product
16A D01 - 1-Pole No 0.0767kg
B216063 - 01730.152000 See product
16A D01 - 3-Pole No 0.041kg
B218110 - 01738.250000 See product
63A D02 - 3-Pole No 0.0426kg
E222874 - 01731.272000 See product
63A D02 - 3-Pole No 0.278kg
F213008 - 01721.400000 See product
63A D02 - 1-Pole No 0.072kg
F216067 - 01722.470000 See product
100A D03 - 1-Pole No 0.22kg
F216573 - 01731.200000 See product
63A D02 - 3-Pole No 0.24kg
H219680 - 01722.480000 See product
100A D03 - 1-Pole No 0.26kg
J200660 - 01720.150000 See product
16A D01 - 1-Pole No 0.068kg
Back to top