Back
Where to buy Contact us
PHP-LFBCA5-MSL

NH fuse-links aM 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • aM: Partial purpose, motor circuit protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
N232496 - NH000AM50V10 See product
10A NH000 - Yes 0.13kg
N232519 - NH2AM50V400 See product
400A NH2 - Yes 0.64kg
P232497 - NH000AM50V16 See product
16A NH000 - Yes 0.13kg
P232520 - NH3AM50V315 See product
315A NH3 - Yes 1.05kg
Q232498 - NH000AM50V20 See product
20A NH000 - Yes 0.13kg
Q232521 - NH3AM50V355 See product
355A NH3 - Yes 1.05kg
R232499 - NH000AM50V25 See product
25A NH000 - Yes 0.13kg
R232522 - NH3AM50V400 See product
400A NH3 - Yes 1.05kg
S232500 - NH000AM50V32 See product
32A NH000 - Yes 0.13kg
S232523 - NH3AM50V425 See product
425A NH3 - Yes 1.05kg
Back to top