NH fuse-links gG 500VAC , top indicator/live gripping-lugs size 4, 4a
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Product data sheets
Brochures and Flyers
- DS-NH-Fuse-Handles-EN
pdf - 804.83 KB
Compliance
- COM-REACH-declaration-0021-NHGG-500V-fuses
pdf - 245.26 KB
- COM-CE-ROHS-declaration-0021-NHGG-500V-fuses
pdf - 197.66 KB
Key features & benefits
Dimensions in accordance with DIN 43 620
Live tags
Top indicator
0% cadmium
Applications
gG: General purpose (protection of cables and LV-networks)
Amperage Range | 400 ... 1600 A |
Speed/Characteristic | gG |
CE Conformity | Yes |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A1034517 - NH4GG50V1250-8 See product
|
1250A | NH4 | - | Yes | 2.59kg |
B1034518 - NH4AGG50V400-8 See product
|
400A | NH4a | - | Yes | 2.59kg |
C1034519 - NH4AGG50V500-8 See product
|
500A | NH4a | - | Yes | 2.59kg |
D1034520 - NH4AGG50V630-8 See product
|
630A | NH4a | - | Yes | 2.59kg |
F1034522 - NH4AGG50V800-8 See product
|
800A | NH4a | - | Yes | 2.59kg |
H1034524 - NH4AGG50V1000-8 See product
|
1000A | NH4a | - | Yes | 2.59kg |
J1034525 - NH4AGG50V1250-8 See product
|
1250A | NH4a | - | Yes | 2.59kg |
K1034526 - NH4AGG50V1600-8 See product
|
1600A | NH4a | - | Yes | 2.59kg |
X1034514 - NH4GG50V630-8 See product
|
630A | NH4 | - | Yes | 2.59kg |
Y1034515 - NH4GG50V800-8 See product
|
800A | NH4 | - | Yes | 2.59kg |