W1203425 - 7.328.125
Series: Smart MULTIVERT® i-Xtensio
NH fuse-switch disconnector MULTIVERT® Size 3 630A 3x1-Pole switching Bus bar system 185mm V-terminal E.on Smart
MERSEN Smart monitoring solution is key to answer to new challenges of the electrical power grid! The development of smart Low voltage grids will enable better understanding of the behavior of local LV networks in the context of decentralization and volatility of renewable power sources and of EV charging stations, among others. Instant monitoring of the network values and status allows a more efficient load & demand management and higher network availability. Critical or heavily loaded network sections can then be specifically monitored to perform preventive maintenance and high service continuity. The most user-friendly and most compatible smart monitoring module for NH vertical fuse switch disconnectors ! The compact module designed by Mersen is by far the simplest to install monitoring device and adapts perfectly to the Multivert i-Xtensio ranges that are available today. The product has been engineered to be fully compatible with Energy Monitoring systems existing on the market and has a very compact design for tremendous functionalities. This device makes the data available for the end-user that can connect directly on the Modbus modules. The modules measures relevant data directly on the fuse switch disconnector and enables the users to access instantaneously to main data of energy consumption.
NH fuse-switch disconnector MULTIVERT® Size 3 630A 3x1-Pole switching Bus bar system 185mm V-terminal E.on Smart
MERSEN Smart monitoring solution is key to answer to new challenges of the electrical power grid! The development of smart Low voltage grids will enable better understanding of the behavior of local LV networks in the context of decentralization and volatility of renewable power sources and of EV charging stations, among others. Instant monitoring of the network values and status allows a more efficient load & demand management and higher network availability. Critical or heavily loaded network sections can then be specifically monitored to perform preventive maintenance and high service continuity. The most user-friendly and most compatible smart monitoring module for NH vertical fuse switch disconnectors ! The compact module designed by Mersen is by far the simplest to install monitoring device and adapts perfectly to the Multivert i-Xtensio ranges that are available today. The product has been engineered to be fully compatible with Energy Monitoring systems existing on the market and has a very compact design for tremendous functionalities. This device makes the data available for the end-user that can connect directly on the Modbus modules. The modules measures relevant data directly on the fuse switch disconnector and enables the users to access instantaneously to main data of energy consumption.
Datasheets
pdf - 1.2 MB
Compliances
pdf - 327.02 KB
pdf - 327.04 KB
pdf - 212.67 KB
pdf - 266.91 KB
Item number | W1203425 |
Catalogue No | 7.328.125 |
Description | NH fuse-switch disconnector MULTIVERT® Size 3 630A 3x1-Pole switching Bus bar system 185mm V-terminal E.on Smart |
EAN/UPC Code | 3605340705096 |
Frequency (Hz) | 50 ... 60 Hz |
Utilization Category | AC 23 B @ Ue = AC 400 V; Ie = 630 A AC 22 B @ Ue = AC 500 V; Ie = 630 A AC 21 B @ Ue = AC 690 V; Ie = 630 A |
Switchability | coupure 3x1-pôle |
ROHS Compliant | Yes |
Fuse Size | 3 |
Design Details | MULTIVERT® 7.328.025 with V-terminals, pre-cabled with 3x CTs 600/1A, 5 VA, class 1, 3-Phase voltage measurements and Smart module SM-RTU/1. Fully compliant to E.on Specification |
Number of Poles | 3-Pole |
Degree of Pollution | 3 |
Rated Impulse Withstand Voltage | 12 kV |
Rated Insulation Voltage | 1000 V |
Rated SC Withstand | 12.6 kA / 1 s |
Max Power dissipation of Fuse Links Pn | 48 W |
Max Power dissipation of Solid Links Pn | 17.5 W |
Power Dissipation by Ith without Fuse-Links | 95 W |
Rated short circuit making capacity with solid links Icm | 16 kA |
Installation Mounting | Bus bar system 185 mm |
Product Width | 3.86 in |
Product Length | 8.78 in |
Product Height | 28.54 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 16.535 lb |
Sell Pack Width | 5.12 in |
Sell Pack Length | 9.45 in |
Sell Pack Height | 31.89 in |
Product group | IEC Fuse Switch Disconnectors |
Product Weight | 13.889 lb |
Conventional Free Air thermal Current With Fuse-Links Ith | 630 A |
Conventional Free Air thermal Current - Solid Links | 800 A |