Ultrasafe 3-Pole Fuse Modules - Class CC Fuses
Mersen UltraSafe™ Fuse Modules have a unique, compact design suited for use with 45mm wide IEC contactors. These modules also offer other features not found on other Class CC and midget UltraSafe fuse holders such as an auxiliary contact option. When the auxiliary is wired to an adjacent contactor the load is dropped out by the contactor immediately once someone tries to open the fuse extractor handle. Additionally, the fuse module features padlock capabilities, compact busbars for line side terminations, and tool free removal from DIN-rail. Yet the fuse modules still incorporate well known UltraSafe features such as IP20 protection, easy operating fuse extraction handles and an open fuse visual indication option.
Mersen UltraSafe™ Fuse Modules have a unique, compact design suited for use with 45mm wide IEC contactors. These modules also offer other features not found on other Class CC and midget UltraSafe fuse holders such as an auxiliary contact option. When the auxiliary is wired to an adjacent contactor the load is dropped out by the contactor immediately once someone tries to open the fuse extractor handle. Additionally, the fuse module features padlock capabilities, compact busbars for line side terminations, and tool free removal from DIN-rail. Yet the fuse modules still incorporate well known UltraSafe features such as IP20 protection, easy operating fuse extraction handles and an open fuse visual indication option.
Product data sheets
- DS-USFM-UltraSafe-Fuse-Modules-Mersen
pdf - 681.53 KB
Key features & benefits
Dedicated 3-pole fuse module
Finger-safe
Compact footprint with 45mm width
Auxiliary contact option (1NO/1NC)
Ability to padlock in OPEN position with 1/4" shank diameter
DIN-rail mount with tool free removal
Quick, easy fuse change
Optional indicator lights
Applications
Primarily for motor circuits to replace circuit breakers for higher SCCR ratings
Other circuits up to 600 volts for control circuits, transformers, etc.
Non-load disconnect
Padlock compliance
RECOMMENDED FUSE USAGE:
USM use with: ATQ, ATM(1), A6Y-2B, A25Z-2, TRM, OTM, A13X-2, A60Q-2, DCT(1)
USCC use with: ATDR, ATMR(1), ATQR
(1) Recommended for DC applications
| Fuse Class | Class CC |
| Short Circuit Current Rating (SCCR) | 200 kA |
| UL Category Code | IZLT |
| CSA File Number | Class 6225-01 File 32169 |
| Harmonized System | 853690 |
| UL File Number | E52283 |
| Degree of Protection (IP) | IP20 |
Reference Finder
Scroll
| Item number | Ampere rating | Fuse size | Fuse Type/Class | Number of poles | Indication System | Product weight |
|---|---|---|---|---|---|---|
|
USFMCC See product
|
30A | - | Class CC | 3-Pole | No | 0.1814kg |
|
USFMCCI See product
|
30A | - | Class CC | 3-Pole | Yes | 0.1814kg |
|
USFMCCM See product
|
30A | - | Class CC | 3-Pole | Yes | 0.2041kg |
|
USFMCCMI See product
|
30A | - | Class CC | 3-Pole | Yes | 0.2041kg |