Product
Q223689 - NH000GG40V4-1
DIN NH Standard fuse-link gG Size NH000 400VAC 4A isolated tags Double indicator Body width 21mm
Read
Product
V233560 - NH4AAM50V1000-8
DIN NH Standard fuse-link aM Size NH4a 500VAC 1000A live tags Top indicator Body width 100 mm
Read
Product
V219668 - NH4AM50V1250-8
DIN NH Standard fuse-link aM Size NH4 500VAC 1250A live tags Top indicator Body width 100 mm
Read
Product
W233561 - NH4AAM50V1250-8
DIN NH Standard fuse-link aM Size NH4a 500VAC 1250A live tags Top indicator Body width 100mm
Read
Series
NH fuse-links aM 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
Read
Product
P227851 - NH000AM69V2
DIN NH Standard fuse-link aM Size NH000 690VAC 2A live tags Double indicator Body width 21mm
Read
Product
Q227852 - NH000AM69V4
DIN NH Standard fuse-link aM Size NH000 690VAC 4A live tags Double indicator Body width 21mm
Read
Product
R227853 - NH000AM69V6
DIN NH Standard fuse-link aM Size NH000 690VAC 6A live tags Double indicator Body width 21mm
Read
Product
L227986 - NH3AM69V500
DIN NH Standard fuse-link aM Size NH3 690VAC 500A live tags Double indicator Body width 71.9mm
Read
Series
NH fuse-links aM 690VAC , top indicator/live gripping-lugs size 4, 4a
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
Read