Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
M1215722 - ABAT15C700-LIA
ABAT Size C, voltage: up to 1500VDC (with L/R≤3ms), Class : aBat, 700A, with LI Long Slotted Blades
Read
Product
N1215723 - ABAT15C800-LIA
ABAT Size C, voltage: up to 1500VDC (with L/R≤3ms), Class : aBat, 800A, with LI Long Slotted Blades
Read
Product
F1200490 - ABAT15C800-AIA
ABAT Size C, voltage : up to 1500VDC (with L/R≤3ms), Class : aBat, 800A, with Metric thread Flush Ends
Read
Product
G1200491 - ABAT15C900-AIA
ABAT Size C, voltage : up to 1500VDC (with L/R≤3ms), Class : aBat, 900A, with Metric thread Flush Ends
Read
Product
G1215717 - ABAT15C550-LIA
ABAT Size C, voltage: up to 1500VDC (with L/R≤3ms), Class : aBat, 550A, with LI Long Slotted Blades
Read
Product
H1200492 - ABAT15C1000-AIB
ABAT Size C, voltage : up to 1500VDC (with L/R≤3ms), Class : aBat, 1000A, with Metric thread Flush Ends
Read
Product
A076038 - FR10AM25V25P
Cylindrical fuse-link aM Size 10x38 IEC 250VAC 25A With Striker
Read
Product
A084985 - FR10AM40V8P
Cylindrical fuse-link aM Size 10x38 IEC 400VAC 8A With Striker
Read
Series
Ferrule fuse-links 10x38 aM 400 to 690VAC
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. Size 10x38 is also available with striker. All cylindrical fuse-links have ceramic bodies and silver-plated contacts.
Cylindrical fuse-links "aM" are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links "aM" are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor.
Our technology and process was designed to ensure highly reliable technical performance.
Read
Product
A213601 - FR10AM50V12
Cylindrical fuse-link aM Size 10x38 IEC 500VAC 12A
Read