Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Series
Protistor® BS88-4 size 17x49 and 2x17x49 aR/gR (GRB, URB), 690VAC
Extremely high breaking capacity fuses:
Protection of power semiconductors as per IEC standard 60269-1 and -4
690V voltage rating as per IEC 33
gR class (current ratings 12 to 90A) as per VDE 636-23
- Clearing all overloads
- Improved safety and protection
- Enabling selective coordination with all fuses within distribution circuit
aR class (current ratings 100A) according to VDE 636-23 and IEC 60269-4
Connection as per:
- German standard DIN 43653/00C
- British standard BS88-4
These fuses are UL Recognized
Read
Series
Protistor® BS88-4 size 17x49 and 2x17x49 aR (URS, URT), 690VAC
Extremely high breaking capacity fuses:
Protection of power semiconductors as per IEC standard 60269-1 and -4
690V voltage rating as per IEC 33
gR class (current ratings 12 to 90A) as per VDE 636-23
- Clearing all overloads
- Improved safety and protection
- Enabling selective coordination with all fuses within distribution circuit
aR class (current ratings 100A) according to VDE 636-23 and IEC 60269-4
Connection as per:
- German standard DIN 43653/00C
- British standard BS88-4
These fuses are UL Recognized
Read
Product
9F59UBC282
ETP 8300V 25K / 15T Configuration: 282
Read
Product
9F59UBC284
ETP 8300V 40K / 25T Configuration: 284
Read
Product
9F59UBC288
ETP 8300V 80K / 50T Configuration: 288
Read
Product
9F59UBE271
ETP 23000V 12K / 8T Configuration: 271
Read
Product
9F59UBE272
ETP 23000V 25K / 15T Configuration: 272
Read
Product
9F59UBE281
ETP 23000V 12K / 8T Configuration: 281
Read
Product
9F59UBE282
ETP 23000V 25K / 15T Configuration: 282
Read
Series
8.3kV ETP Fuses
The Sure Guard ETP back-up current-limiting fuses are designed to protect overhead distribution systems and are used in series with another protective device (such as an expulsion fuse). This combination limits the high-fault current to a safe level, thus providing protection through the complete range. As its name implies, the “ETP” is for External Transformer Protection. For conventional transformers protected by expulsion-fuses cutouts, the ETP can be installed in series with the cutout. For self protected transformers, the ETP can be applied on the high-voltage bushing in series with the internal transformer expulsion fuse.
Read