Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Series
Offset Tag fuse-links gM 415VAC/240VDC
The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. These fuses are designed for : “General purpose use” motor protection (gM type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors.
Read
Product
N212647 - D03GG40V100
DIN D0 Fuse-link Neozed gG Size D03 400VAC 250VDC 100A Color code Red Packaging quantity 10
Read
Series
Offset Tag fuse-links gG 550VAC/250VDC
The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. These fuses are designed for : “General purpose use” protection (gG type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors.
Read
Series
Offset Tag fuse-links gG 690VAC/460VDC
The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. These fuses are designed for : “General purpose use” protection (gG type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors.
Read
Series
Offset Tag fuse-links gG 415VAC/240VDC
The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. These fuses are designed for : “General purpose use” protection (gG type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors.
Read
Series
Offset Tag fuse-links gG 415VAC/250VDC
The fuse complies with standard EN 60269-2 section II and standard BS 88 part 2. These fuses are designed for : “General purpose use” protection (gG type). This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by other fuses of higher rating in their range. They are screwed into fuseholders or bolted directly onto busbars, or in fuse interruptors disconnectors.
Read
Product
H211607 - D02AM44V20
DIN D0 Fuse-link Neozed aM Size D02 440VAC 20A Color code Blue Packaging quantity 10
Read
Product
F212640 - D02AM44V25
DIN D0 Fuse-link Neozed aM Size D02 440VAC 25A Color code Yellow Packaging quantity 10
Read
Product
J213655 - D02AM44V35
DIN D0 Fuse-link Neozed aM Size D02 440VAC 35A Color code Black Packaging quantity 10
Read
Series
NEOZED D0 fuse-links gG 400/440VAC
The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non trained persons and can also be replaced by them.
The system is the most modern of the screw systems and designed for 400VAC/250VDC networks.
The D0 fuse range comprises the standardized fuse sizes D01, D02 and D03.
The range of applications for D0 fuse-links for general application is the protection of cables and power lines. They limit and cut off unacceptable overcurrents and short circuit currents up to their nominal breaking capacity. D0 fuse-links "gG" also protect equipments and installations against dynamic effects of high short circuit currents.
Read