Back
Where to buy Contact us
PHP-LFBCATI54-MSL

NH fuse-links aM 500VAC , top indicator/live gripping-lugs size 4, 4a

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • aM: Partial purpose, motor circuit protection

Technical Specifications
Amperage Range 400 ... 1250 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

11 references in this series

Scroll

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
E222115 - NH4AM50V630-8 See product
630A NH4 - Yes 2.18kg
P233555 - NH4AM50V400-8 See product
400A NH4 - Yes 2.18kg
Q233556 - NH4AM50V500-8 See product
500A NH4 - Yes 2.18kg
R233557 - NH4AAM50V500-8 See product
500A NH4a - Yes 2.2kg
S219137 - NH4AM50V1000-8 See product
1000A NH4 - Yes 2.18kg
S233558 - NH4AAM50V630-8 See product
630A NH4a - Yes 2.2kg
T233559 - NH4AAM50V800-8 See product
800A NH4a - Yes 2.2kg
V219668 - NH4AM50V1250-8 See product
1250A NH4 - Yes 2.18kg
V222865 - NH4AM50V800-8 See product
800A NH4 - Yes 2.18kg
V233560 - NH4AAM50V1000-8 See product
1000A NH4a - Yes 2.2kg