Back
Where to buy Contact us
PHP-LFBCG4-MSL

NH fuse-links gG 400VAC , double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • Lead free contact blades

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
G223727 - NH2GG40V100 See product
100A NH2 - Yes 0.42kg
H223682 - NH000GG40V35 See product
35A NH000 - Yes 0.133kg
H223728 - NH2GG40V125 See product
125A NH2 - Yes 0.42kg
J223683 - NH000GG40V40 See product
40A NH000 - Yes 0.133kg
J223706 - NH1GG40V35 See product
35A NH1 - Yes 0.28kg
J223729 - NH2GG40V160 See product
160A NH2 - Yes 0.42kg
K223684 - NH000GG40V50 See product
50A NH000 - Yes 0.133kg
K223707 - NH1GG40V50 See product
50A NH1 - Yes 0.28kg
K223730 - NH2GG40V200 See product
200A NH2 - Yes 0.42kg
L223685 - NH000GG40V63 See product
63A NH000 - Yes 0.133kg
Back to top