Back
Where to buy Contact us
PHP-LFBCS5-MSL

NH fuse-links gG 500VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
E212639 - NH3GG50V355-1 See product
355A NH3 - Yes 0.65kg
E213651 - NH0GG50V16-1 See product
16A NH0 - Yes 0.23kg
E216204 - NH2GG50V200-1 See product
200A NH2 - Yes 0.42kg
E218251 - NH1GG50V250-1 See product
250A NH1 - Yes 0.42kg
F211605 - NH2GG50V80-1 See product
80A NH2 - Yes 0.42kg
F213997 - NH000GG50V16-1 See product
16A NH000 - Yes 0.13kg
F216205 - NH3GG50V500-1 See product
500A NH3 - Yes 1.05kg
F218091 - NH000GG50V20-1 See product
20A NH000 - Yes 0.13kg
F218252 - NH2GG50V250-1 See product
250A NH2 - Yes 0.42kg
F219287 - NH0GG50V160-1 See product
160A NH0 - Yes 0.23kg
Back to top