Back
Where to buy Contact us
PHP-LFBCS5-MSL

NH fuse-links gG 500VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
G201187 - NH000GG50V35-1 See product
35A NH000 - Yes 0.13kg
G201348 - NH1GG50V35-1 See product
35A NH1 - Yes 0.28kg
G211606 - NH3GG50V315-1 See product
315A NH3 - Yes 0.65kg
H201349 - NH2GG50V50-1 See product
50A NH2 - Yes 0.42kg
H213654 - NH3GG50V400-1 See product
400A NH3 - Yes 0.65kg
H219289 - NH2GG50V300-1 See product
300A NH2 - Yes 0.6433kg
H219818 - NH1GG50V16-1 See product
16A NH1 - Yes 0.28kg
J201189 - NH000GG50V100-1 See product
100A NH000 - Yes 0.13kg
J201189C - NH000GG50V100-1/3 See product
100A NH000 - Yes 0.13kg
J201350 - NH3GG50V250-1 See product
250A NH3 - Yes 0.65kg
Back to top