Back
Where to buy Contact us
PHP-LFBCS5-MSL

NH fuse-links gG 500VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
Q211085 - NH1GG50V40-1 See product
40A NH1 - Yes 0.28kg
Q217226 - NH2GG50V224-1 See product
224A NH2 - Yes 0.42kg
R200805 - NH1GG50V32-1 See product
32A NH1 - Yes 0.28kg
R212466 - NH000GG50V63-1 See product
63A NH000 - Yes 0.13kg
R212466C - NH000GG50V63-1/3 See product
63A NH000 - Yes 0.13kg
S200806 - NH2GG50V40-1 See product
40A NH2 - Yes 0.42kg
S211087 - NH3GG50V300-1 See product
300A NH3 - Yes 0.65kg
S214675 - NH3GG50V425-1 See product
425A NH3 - Yes 1.05kg
S218769 - NH0GG50V125-1 See product
125A NH0 - Yes 0.23kg
T200807 - NH2GG50V400-1 See product
400A NH2 - Yes 0.6433kg
Back to top