Back
Where to buy Contact us
PHP-LFBCS5-MSL

NH fuse-links gG 500VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
T201865 - NH2GG50V63-1 See product
63A NH2 - Yes 0.42kg
T217735 - NH0GG50V80-1 See product
80A NH0 - Yes 0.23kg
T222496 - NH1GG50V20-1 See product
20A NH1 - Yes 0.28kg
T236043 - NH1GG50V125-1 See product
125A NH1 - Yes 0.28kg
V200808 - NH00GG50V125-1 See product
125A NH00 - Yes 0.2kg
V215183 - NH0GG50V32-1 See product
32A NH0 - Yes 0.23kg
V215528 - NH000GG50V10-1 See product
10A NH000 - Yes 0.13kg
V217736 - NH1GG50V224-1 See product
224A NH1 - Yes 0.42kg
W201867 - NH00GG50V160-1 See product
160A NH00 - Yes 0.2kg
W215184 - NH1GG50V100-1 See product
100A NH1 - Yes 0.28kg
Back to top