Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 425 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
K229710 - NH000GG69V20-1 See product
20A NH000 - Yes 0.14kg
K229756 - NH2GG69V35-1 See product
35A NH2 - Yes 0.43kg
L229711 - NH000GG69V25-1 See product
25A NH000 - Yes 0.14kg
L229734 - NH0GG69V50-1 See product
50A NH0 - Yes 0.25kg
L229757 - NH2GG69V40-1 See product
40A NH2 - Yes 0.43kg
M229712 - NH000GG69V32-1 See product
32A NH000 - Yes 0.14kg
M229735 - NH0GG69V63-1 See product
63A NH0 - Yes 0.25kg
M229758 - NH2GG69V50-1 See product
50A NH2 - Yes 0.43kg
N229713 - NH000GG69V35-1 See product
35A NH000 - Yes 0.14kg
N229736 - NH0GG69V80-1 See product
80A NH0 - Yes 0.25kg