Back
Where to buy Contact us
PHP-LFBCS6-MSL

NH fuse-links gG 690VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Isolated metal gripping lugs (SGL)

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 425 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
X229744 - NH1GG69V35-1 See product
35A NH1 - Yes 0.29kg
X229767 - NH2GG69V300-1 See product
300A NH2 - Yes 0.64kg
Y229722 - NH00GG69V63-1 See product
63A NH00 - Yes 0.2kg
Y229745 - NH1GG69V40-1 See product
40A NH1 - Yes 0.29kg
Y229768 - NH2GG69V315-1 See product
315A NH2 - Yes 0.64kg
Z229723 - NH00GG69V80-1 See product
80A NH00 - Yes 0.2kg
Z229746 - NH1GG69V50-1 See product
50A NH1 - Yes 0.29kg
Z229769 - NH2GG69V355-1 See product
355A NH2 - Yes 0.64kg
Back to top