Back
Where to buy Contact us
PHP-LFBCG6-MSL

NH fuse-links gG 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 500 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
W228478 - NH1GG69V25 See product
25A NH1 - Yes 0.27kg
W228501 - NH2GG69V300 See product
300A NH2 - Yes 0.64kg
W233262 - NH1GG69V250 See product
250A NH1 - Yes 0.42kg
X228456 - NH00GG69V40 See product
40A NH00 - Yes 0.2kg
X228479 - NH1GG69V32 See product
32A NH1 - Yes 0.27kg
X228502 - NH2GG69V315 See product
315A NH2 - Yes 0.64kg
Y228457 - NH00GG69V50 See product
50A NH00 - Yes 0.2kg
Y228480 - NH1GG69V35 See product
35A NH1 - Yes 0.27kg
Y228503 - NH2GG69V355 See product
355A NH2 - Yes 0.64kg
Z228458 - NH00GG69V63 See product
63A NH00 - Yes 0.2kg
Back to top