Back
Where to buy Contact us
PHP-LFBCG6-MSL

NH fuse-links gG 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications

Amperage Range 2 ... 500 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
K228491 - NH2GG69V40 See product
40A NH2 - Yes 0.42kg
L228446 - NH000GG69V20 See product
20A NH000 - Yes 0.125kg
L228469 - NH0GG69V40 See product
40A NH0 - Yes 0.27kg
L228492 - NH2GG69V50 See product
50A NH2 - Yes 0.42kg
M228447 - NH000GG69V25 See product
25A NH000 - Yes 0.125kg
M228470 - NH0GG69V50 See product
50A NH0 - Yes 0.27kg
M228493 - NH2GG69V63 See product
63A NH2 - Yes 0.42kg
N228448 - NH000GG69V32 See product
32A NH000 - Yes 0.125kg
N228471 - NH0GG69V63 See product
63A NH0 - Yes 0.27kg
N228494 - NH2GG69V80 See product
80A NH2 - Yes 0.42kg
Back to top