NH fuse-links gG 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 500 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
A228459 - NH00GG69V80 See product
80A NH00 - Yes 0.2kg
A228482 - NH1GG69V50 See product
50A NH1 - Yes 0.27kg
A228505 - NH3GG69V300 See product
300A NH3 - Yes 0.65kg
B228460 - NH00GG69V100 See product
100A NH00 - Yes 0.2kg
B228483 - NH1GG69V63 See product
63A NH1 - Yes 0.27kg
B228506 - NH3GG69V315 See product
315A NH3 - Yes 0.65kg
C228461 - NH00GG69V125 See product
125A NH00 - Yes 0.2kg
C228484 - NH1GG69V80 See product
80A NH1 - Yes 0.27kg
C228507 - NH3GG69V355 See product
355A NH3 - Yes 0.65kg
D228462 - NH0GG69V6 See product
6A NH0 - Yes 0.27kg
Back to top