M60J22
Series: UL98 Fused Switch
UL 98 Fusible Switch 600VAC Class J 60A 4-Pole Configuration: 2-2
Mersen’s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are “service entrance” devices capable of fully rated load-break and load-make. While longterm safety, reliability, and functionality are always paramount in the design of our products, these switches are also engineered to have the smallest footprint. The modular design allows placement of the handle anywhere amongst the poles. The fuse doors cannot open when the switch is in the “ON” position, and all switches are double-break, which isolates both fuse clips from voltage during fuse replacement. The switches’ “Test” position allows actuation of the auxiliary contacts without main power. Power taps enable energizing a CPT or surge device without the need for a separate terminal block. A wide range of ergonomic handles and accessories is available.
UL 98 Fusible Switch 600VAC Class J 60A 4-Pole Configuration: 2-2
Mersen’s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are “service entrance” devices capable of fully rated load-break and load-make. While longterm safety, reliability, and functionality are always paramount in the design of our products, these switches are also engineered to have the smallest footprint. The modular design allows placement of the handle anywhere amongst the poles. The fuse doors cannot open when the switch is in the “ON” position, and all switches are double-break, which isolates both fuse clips from voltage during fuse replacement. The switches’ “Test” position allows actuation of the auxiliary contacts without main power. Power taps enable energizing a CPT or surge device without the need for a separate terminal block. A wide range of ergonomic handles and accessories is available.
Datasheets
pdf - 1.18 MB
Item number | M60J22 |
Description | UL 98 Fusible Switch 600VAC Class J 60A 4-Pole Configuration: 2-2 |
EAN/UPC Code | 3605340561159 |
Rated voltage AC UL | 600 V |
Rated voltage DC UL | 250 V |
Ampere Rating | 60 A |
ROHS Compliant | Yes |
AC or DC | AC/DC |
Short Circuit Current Rating (SCCR) | 200 kA |
Fuse Type/Class | Class J |
Short Circuit Rating (Class J) | 200 kA |
Short Circuit Rating (Standalone) | 200 kA |
Number of Poles | 4-Pole |
Wiring range | #14-4 |
Connection/Terminal Type | Box |
Torque Rating | 30 lb-in |
Max Fuse Rating | 60 A |
Max Horsepower Rating/FLA | 3-Phase: 240V 15HP, 480V 30HP, 600V 50HP |
Contact Type | Double coupure |
Rated Insulation Voltage | 1000 V |
Installation Mounting | Direct Screw Mount |
Product Width | 7.2 in |
Product Length | 3.94 in |
Product Height | 4.65 in |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 3.32 lb |
Sell Pack Width | 7.56 in |
Sell Pack Length | 7.56 in |
Sell Pack Height | 7.56 in |
Product group | UL/CSA Switches |
Product Weight | 3.17 lb |