Back
Where to buy Contact us
PHP-BSFPgG-MSL

BS88 Fusibles piliers d alimentation gG 415 VAC

Approvals & Standards
ASTA 20
EN 60269-2
BS88-2

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

Key features & benefits

  • Better coordination

  • Immediate isolation

  • Ensures fire safety

Applications

  • Feeder pillar for street lighting

  • Electricity Supply Industries in distribution pillars

  • Open type substation boards

  • Heavy duty service cut-outs

  • Underground disconnecting boxes

Technical Specifications

Voltage Range 415 VAC
Amperage Range 20-630A
Speed/Characteristic gG
CE Conformity Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
P1003894 - BJU42V080PA See product
80A 110x36 21000A²s No 0.185kg
Q1003895 - BJU42V100PA See product
100A 110x36 37000A²s No 0.185kg
R1003896 - BJU42V125PA See product
125A 110x36 74700A²s No 0.185kg
S1003897 - BJU42V160PA See product
160A 110x36 168000A²s No 0.185kg
V1003899 - BJU42V020SA See product
20A 130x36 1125A²s No 0.281kg
V1003922 - BJU42V200SA See product
200A 130x36 256500A²s No 0.281kg
W1003900 - BJU42V025SA See product
25A 130x36 1890A²s No 0.281kg
W1003923 - BJU42V250PB See product
250A 110x42 270000A²s No 0.244kg
X1003901 - BJU42V032SA See product
32A 130x36 3000A²s No 0.281kg
Y1003902 - BJU42V040SA See product
40A 130x36 5850A²s No 0.281kg
Back to top