Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
Y229745 - NH1GG69V40-1
DIN NH Standard fuse-link gG Size NH1 690VAC 400VDC 40A isolated tags Double indicator Body width 30 mm
Read
Series
NH fuse-links gG 500VAC , middle indicator/live gripping-lugs size 4, 4a
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Read
Product
K1054283 - NH4GG50V400
DIN NH Standard fuse-link gG Size NH4 500VAC 250VDC 400A live tags Center indicator Body width 100 mm
Read
Product
R1054289 - NH4AGG50V400
DIN NH Standard fuse-link gG Size NH4a 500VAC 250VDC 400A live tags Center indicator Body width 100 mm
Read
Product
L1054284 - NH4GG50V500
DIN NH Standard fuse-link gG Size NH4 500VAC 250VDC 500A live tags Center indicator Body width 100 mm
Read
Product
N214004 - NH4GG69V400-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 400A live tags Top indicator Body width 100 mm
Read
Product
Y215025 - NH4GG69V500-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 500A live tags Top indicator Body width 100 mm
Read
Product
E215537 - NH4GG69V630-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 630A live tags Top indicator Body width 100 mm
Read
Product
K216554 - NH4GG69V800-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 800A live tags Top indicator Body width 100 mm
Read
Series
NH fuse-links gTr 400VAC, middle indicator/isolated gripping-lugs size 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base, (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.
NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1,3 times nominal current for up to 10 hours. The fuse link operates at 1,5 times nominal transformer current within 2 hours.
Read