NH fuse-links aM 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • aM: Partial purpose, motor circuit protection

Technical Specifications
Amperage Range 2 ... 500 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
E227888 - NH1AM69V32 See product
32A NH1 - Yes 0.43kg
E227980 - NH3AM69V300 See product
300A NH3 - Yes 1.05kg
F227866 - NH00AM69V80 See product
80A NH00 - Yes 0.2kg
F227889 - NH1AM69V35 See product
35A NH1 - Yes 0.43kg
F227981 - NH3AM69V315 See product
315A NH3 - Yes 1.05kg
G227867 - NH00AM69V100 See product
100A NH00 - Yes 0.2kg
G227890 - NH1AM69V40 See product
40A NH1 - Yes 0.43kg
G227982 - NH3AM69V355 See product
355A NH3 - Yes 1.05kg
H227868 - NH00AM69V125 See product
125A NH00 - Yes 0.2kg
H227891 - NH1AM69V50 See product
50A NH1 - Yes 0.43kg
Back to top