Back
Where to buy Contact us
PHP-LFBCA6-MSL

NH fuse-links aM 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • aM: Partial purpose, motor circuit protection

Technical Specifications

Amperage Range 2 ... 500 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
H227983 - NH3AM69V400 See product
400A NH3 - Yes 1.05kg
J227892 - NH1AM69V63 See product
63A NH1 - Yes 0.43kg
J227984 - NH3AM69V425 See product
425A NH3 - Yes 1.05kg
K227893 - NH1AM69V80 See product
80A NH1 - Yes 0.43kg
K227985 - NH3AM69V450 See product
450A NH3 - Yes 1.05kg
L227871 - NH0AM69V10 See product
10A NH0 - Yes 0.26kg
L227894 - NH1AM69V100 See product
100A NH1 - Yes 0.43kg
L227963 - NH2AM69V35 See product
35A NH2 - Yes 0.64kg
L227986 - NH3AM69V500 See product
500A NH3 - Yes 1.05kg
M227872 - NH0AM69V16 See product
16A NH0 - Yes 0.26kg
Back to top