Back
Where to buy Contact us
PHP-LFBCA6-MSL

NH fuse-links aM 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.

Key features & benefits

  • Dimensions according to DIN 43 620 parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • 0% cadmium

Applications

  • aM: Partial purpose, motor circuit protection

Technical Specifications

Amperage Range 2 ... 500 A
Speed/Characteristic aM
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
T227855 - NH000AM69V16 See product
16A NH000 - Yes 0.133kg
T227878 - NH0AM69V50 See product
50A NH0 - Yes 0.26kg
T227970 - NH2AM69V160 See product
160A NH2 - Yes 0.64kg
V227856 - NH000AM69V20 See product
20A NH000 - Yes 0.133kg
V227879 - NH0AM69V63 See product
63A NH0 - Yes 0.26kg
V227971 - NH2AM69V200 See product
200A NH2 - Yes 0.64kg
W227857 - NH000AM69V25 See product
25A NH000 - Yes 0.133kg
W227880 - NH0AM69V80 See product
80A NH0 - Yes 0.26kg
W227972 - NH2AM69V224 See product
224A NH2 - Yes 0.64kg
X227858 - NH000AM69V32 See product
32A NH000 - Yes 0.133kg
Back to top